A probe reads the coating over the metal
For suitable coating and metal combinations, a thickness gauge uses magnetic or eddy-current principles to measure the coating without cutting it. Magnetic instruments are used for appropriate coatings over steel; eddy-current instruments are used for suitable nonconductive coatings over nonferrous metals. The instrument and probe must match the substrate and coating.
The number is dry-film thickness
Dry-film thickness, often shortened to DFT, describes the thickness of the coating after drying. It is commonly recorded in mils or micrometres. A mil is one thousandth of an inch. The manufacturer and project specification establish the acceptable range for the coating system.
Verify the gauge before relying on it
Calibration, verification and adjustment are different activities. A field accuracy check uses an appropriate reference standard of known thickness. Follow the instrument instructions for verification and any substrate-specific adjustment. Surface roughness, geometry and access can affect the measurement approach.
Inspect to the agreed plan
One convenient reading does not describe an entire structure or component. The project inspection plan establishes measurement locations, sampling, acceptance criteria and reporting. Record the results against identifiable areas or piece marks so the inspection can be traced to the work.
Thickness is one part of quality control
Film build is reviewed alongside preparation, application conditions, recoat timing, cure and any other required tests. Norvex coordinates these checkpoints for specified field and shop coating packages in Chicago and Northwest Indiana.